MCM Automated Treatment System Control Functional Area
Description
Remotely controls automated roadway treatment systems (to disperse anti-icing chemicals, etc.) directly, or via control of the environmental sensors that activate the treatment systems automatically in the field.
Included In
Functional Requirements
| ID | Requirement |
|---|
| 1 | The center shall remotely control automated roadway treatment systems. Treatments can be in the form of fog dispersion, anti-icing chemicals, etc. |
| 2 | The center shall remotely control the environmental sensors that upon detecting changes in environmental or atmospheric conditions, automatically activate roadway treatment systems. |
| 3 | The center shall collect automated roadway treatment system and associated environmental sensor operational status. |
| 4 | The center shall collect automated roadway treatment system and associated environmental sensor fault data and request repair. |
| 5 | The center shall accept requests for automated roadway treatment system activation from center personnel. |